TLP+™ Options

Options for the Model 4002 TLP+™

20 Amp Option – Model 4002-01

The 20A Option is “True 20 Amp” pulse capability and provides 1,000 volts to an open and 20 Amps through a short.  Note: the control box will need to be returned to factory for modification.

  • This option also allows user to analyze HBM and/or HMM circuits for operation characteristics and immunity.

500ns Wide Pulse Option – Model 4002-02

The Wide Pulse Option is up to 500ns pulse width and provides one (1) External Charge Line (length of your choice).  Note: customer must specify what length is needed (pulse width in ns); For example, an External Charge Line for 500ns pulse width is Model 46001-500; an External Charge Line for 400ns pulse width is Model 46001-400, etc.  Note: the control box will need to be returned to factory for modification.

1500ns Wide Pulse Option – Model 4002-08

Requires 4002-02 500ns Wide Pulse Option; Includes (1) 1000ns Charge Line that is used with the external 500ns (425ns actual) Charge Line to achieve the 1500ns pulse width.  Note:  1500ns Wide Pulse Option is limited to below 10A max.

Combo Option – Model 4002-0102

The Combo Option includes both the 20A option and wide pulse option, listed above. Note: the control box will need to be returned to factory for modification.

Negative Pulse Option – Model 4002-03

The Negative Pulse Option adds an inverter to the pulse circuit; this option is easily installed by user.

30 Amp Option Bundle – Model 4002-05

The 30A Option Bundle provides “True 30 Amp” pulse capability and provides 1,500 volts to an open and 30 Amps through a short.  Note: the control box will need to be returned to Barth for modification.

  • The 30A Option Bundle includes a CPU with T3600 specifications or higher and is required to run the 30A option software, DELL Precision T3600 with Xeon Processor, 4GB Ram, 500GB hard drive, 19” Flat Screen Monitor, Keyboard, Mouse, Windows® 7 OS, and the latest version of BSSP (1 yr subscription).
  • This option also allows user to analyze HBM and/or HMM circuits for operation characteristics and immunity.

Pulsed Bias Box Option – Model 4002-07

The Pulsed Bias Box Option is AC Powered and provides an automatic bypass connection to preserve the leakage test capacity that occurs between TLP stress pulses.  This option is user installed.

  • Integration into the Model 4002 control software to support connection and control of an Agilent E3646A dual output DC power supply.  The bias voltage range will be 0-20V; supply can provide 3A at 0-8V and 1.5A at 0-20V. The practical current of course will be limited by the needle to pad constraints.
  • Hardware to facilitate connection of the bias supply voltage to the TLP pulsed connection.  Includes a new 1U rack mount module that replaces existing external switches/DUT panel.
  • Agilent E3646A dual output DC power supply

Options for the Model 4003 TLP+™

500ns Wide Pulse Option – Model 4003-02

The Wide Pulse Option is up to 500ns pulse width and provides one (1) External Charge Line (length of your choice).  Note:  the control box will need to be returned to factory for modification.

30 Amp Option Bundle – Model 4003-05

The 30A Option Bundle provides “True 30 Amp” pulse capability and provides 1,500 volts to an open and 30 Amps through a short.  Note:  the control box will need to be returned to Barth for modification.

  • The 30A Option Bundle includes a CPU with T3600 specifications or higher and is required to run the 30A option software, DELL Precision T3600 with Xeon Processor, 4GB Ram, 500GB hard drive, 19” Flat Screen Monitor, Keyboard, Mouse, Windows® 7 OS, and the latest version of BSSP (1 yr subscription).
  • This option also allows user to analyze HBM and/or HMM circuits for operation characteristics and immunity.

Pulsed Bias Option – Model 4003-07

The Pulsed Bias Option is AC Powered and provides an automatic bypass connection to preserve the leakage test capacity that occurs between TLP stress pulses.  Note:  the control box will need to be returned to factory for modification.

1500ns Wide Pulse Option – Model 4003-08

Requires 4003-02 500ns Wide Pulse Option; Includes (1) 1000ns Charge Line that is used with the external 500ns (425ns actual) Charge Line to achieve the 1500ns pulse width.  Note:  1500ns Wide Pulse Option is limited to below 10A max.

Keithley Model 2400 Upgrade Option – 4003-11

Replaces the Keithley 6487 Model.

580-NFT

80ns Ramp Generator.  Call our office for details.